Honeywell Fan CL60PM User Manual

Portable Evaporative Air Cooler  
OWNER’S MANUAL  
Read and save these instructions before use  
Model: CL60PM  
Voltage rating: 220-240V`50Hz  
Power rating: 220W  
For product inquiries or support, visit www.honeywellaircoolers.com  
Or call Tel +44 (0) 1477 539 500 Fax +44 (0)1477 539 530  
Made in P.R.C.  
 
INDEX  
Readall instructions carefully before setting up and operating the unit, and please keep this  
instruction manual for future reference. This manual is designed to provide you with  
important information needed to setup, operate, maintain and troubleshoot your cooler.  
Failure to follow these instructions may damage and/or impair its operation and void  
the warranty.  
SECTION  
PAGE  
2
3
5
7
8
1. THANK YOU .........................................................................................................  
2. USER TIPS ...........................................................................................................  
3. SAFETY RULES ...................................................................................................  
4. PARTS DESCRIPTION ........................................................................................  
5. USE & OPERATION .............................................................................................  
Installing Hose Adapter and Float Valve / Fill Water  
8
9
Control Knobs .................................................................................................  
6. CLEANING & MAINTENANCE .............................................................................  
7. TROUBLESHOOTING GUIDE .............................................................................  
8. TECHNICAL SPECIFICATIONS ...........................................................................  
9. ELECTRICAL WIRING DIAGRAM ........................................................................  
10. WARRANTY .......................................................................................................  
10  
12  
14  
14  
15  
1
 
THANK YOU  
THANK YOU!  
Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum  
cooling performance from your unit, first fill it with water.  
Please readtheseinstructions carefully.  
2
 
USER TIPS  
COOL~EFFICIENT~NATURAL  
Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake.This  
breezedrops thetemperatureandhas arelaxingcoolingeffect.  
The evaporative air cooler cools the air by means of the evaporation of water. When water  
evaporates into the air, the result is a mixture of air and water molecules. This chemical change  
requires heat which is taken from the water molecules, resulting in cooler air propelled from the  
unit.  
Honeycomb Cooling Media  
Pump  
Water  
Evaporative Air Cooling Mechanism  
3
 
USER TIPS  
The recommended maximum relative humidity level is 60% or  
less, which allows a noticeable temperature decrease. The  
temperature decrease will be greater in drier climates because  
higherevaporationoccurs whenthehumidityis low.  
The evaporative air cooler should not be used in enclosed  
spaces. It must be kept level and there must be water in the  
water tank. The room should have doors and windows opened  
to allow free air flow. The evaporative air cooler works best  
when placed near an open window, so that outside air is drawn  
into the evaporative air cooler, the air circulates in the room, and  
exits via the door. The maximum cooling effect is felt when a  
person is in the flow of air coming out of the evaporative air  
cooler.  
The evaporative air cooler can also be used to humidify dry air  
during the cool weather months. To be used for humidification  
the windows and doors should be closed to allow the humidified  
air to accumulate. The evaporative air cooler is not an air  
conditioner as it does not use a compressor or refrigerant gas. It  
should not be expected to cool as to a selected, fixed  
temperature like a refrigerated air conditioner.  
NOTE  
When the product is used for the first time the Honeycomb  
cooling media will have an odour which will dissipate in a week  
orsoof initial use.  
4
 
SAFETY RULES  
READ ANDSAVE THESE INSTRUCTIONS:  
When usingelectrical appliances, basic safetyprecautionsshouldalways befollowed:  
Your cooler runs on 220-240 Volt AC, 50 Hz current.  
Check the household voltage to ensure it matches the  
appliance's rate specification.  
220 -240Volt AC  
50 Hz  
Before operating the product remove it from its packaging  
andcheckitisingoodcondition.  
DO NOT operate any product with a damaged cord or plug.  
We recommend not to use an extension cord with this  
appliance.  
SHOCK HAZARD  
DO NOT the run power cord under carpeting, or cover it with  
rugs or runners. Arrange the cord away from areas where it  
maybetrippedover.  
Alwaysunplugtheproductbeforerefillingthewatertank.  
Always unplug the appliance from the power source before  
cleaning, servicingorrelocatingtheunit.  
WATER LEVEL INDICATOR  
• Remove the power cord from the electrical receptacle by  
grasping and pulling on the power cord plug-end only, never  
pull thecord.  
• DO NOT use the product in areas where gasoline, paint or  
otherflammablegoods andobjectsarestored.  
When using the ''Cool'' setting, please check the water  
tank to ensure it is full. Operation of this unit on the  
''Cool'' setting with an empty tank may result in damage  
tothewater pump.  
5
 
SAFETY RULES  
• DO NOT attempt repair or adjust any electrical or mechanical  
functions of thecooler,as thismayvoidthewarranty.  
DO NOT cover the air inlet or outlet on the appliance as this  
maycausemotordamage.  
• DO NOT insert or allow objects to enter any ventilation or  
exhaust opening as this may damage the product and could  
causeanelectricalshockorfire.  
DO NOT operate with the Honeycomb media removed as this  
will overloadanddamagethemotor.  
Water / Ice compartment  
• DO NOT leave the appliance operating unattended for any  
extendedperiodof time.  
DO NOT let children play with this appliance, packaging or  
plasticbags.  
• If the unit is damaged or it malfunctions, do not continue to  
operate it. Refer to the troubleshooting section and /or please  
seek professional advice.  
• Placetheunitonalevelfloor.  
• This product is not intended for use in wet or damp locations.  
Never locate the product where it may fall into a bathtub or  
other water container. DO NOT use in bathrooms.  
• Whenitis notinusealwaysstoreinadryarea.  
• This appliance is not intended for use by persons (including  
children or elderly) with reduced physical, sensory or mental  
capabilities, or lack of experience and knowledge, unless they  
have been given supervision or instruction concerning use of  
theappliancebyapersonresponsiblefortheirsafety.  
• Alwaysgripthesidehandlestomovetheunit.  
FLOOR LEVEL  
6
 
PARTS DESCRIPTION  
1 Water Inlet  
2 Handle  
3 Right Panel  
8 Water Level Indicator  
9 Control Panel  
10 Left Panel  
4 Lever for Horizontal Louvres 11 Continuous Water Inlet  
5 Water Tank  
6 Castors  
7 Horizontal Louvres  
12 Drain Plug  
13 Manual Water Inlet  
14 Back Panel  
CONTROL PANEL  
7
 
USE & OPERATION  
INSTALLING HOSE ADAPTER AND FLOAT VALVE  
• Connect the garden hose Connector and turn on the water.  
• Verify water tight connections by visually examining both  
the float/hose connections.  
Hose Connector  
FILLING WATER  
Water can be filled into the air cooler by  
Continuous water supply  
Connect a garden hose to the continuous water supply inlet.  
Manual operation  
Water can be poured into the unit from the back.  
Water compartment  
Water can be put into the tank through the top opening.  
There is a hole for water to flow into the tank.  
Water compartment  
8
 
USE & OPERATION  
CONTROL KNOBS  
SPEED / ON - OFF  
Connect to the power supply and turn the Speed knob. The fan  
will start. Change the speed from 1 for Low to 2 for Medium to  
3 High. To switch OFF the unit turn the Speed know to "0".  
0
3
2
1
SPEED  
COOL  
Turn the Cool knob to ON to start the cooling. It takes a few  
minutes to obtain the full effect from this mode.  
OFF ON  
SWING  
Vertical Louvres  
COOL  
Turn the SWING knob to 'ON'. The louvres will begin to move  
from right to left automatically.  
OFF ON  
SWING  
Horizontal Louvres  
Manually adjust the horizontal louvres to change vertical airflow.  
9
 
 
CLEANING & MAINTENANCE  
WARNING  
Before cleaning the unit, switch it to the ''OFF'' position  
and remove the plug from the power socket.  
To clean the outside, use a damp cloth to remove dirt and  
dust.  
Never use detergents, corrosive elements or any chemicals  
to clean this product.  
When the product is not in use, store the unit in a dry place  
out of direct sunlight..  
CLEANING AND DRAINING THEWATERTANK  
To refill the tank during operation, turn the power ''OFF''  
and disconnecttheunitfromthepowersupply.  
To clean the water tank, turn the unit ''OFF'' and disconnect  
the power supply. Move the unit to a location where it can  
be drained and remove the drain plug (see number 12 on  
parts description on page 7). Once the tank is empty, refill it  
with clean water and drain it again. This should be repeated  
weekly to maintain the integrity of the unit and to remove  
particlesfilteredfromtheair.  
Once the tank is clean, refill the water tank. The unit is now  
ready tobeusedagain.  
10  
 
CLEANING & MAINTENANCE  
MAINTAING AND CHANGING THE HONEYCOMB  
The appliance is supplied with Honeycomb cooling media.  
Draining the water reservoir and refilling with fresh water at  
least once a week will greatly reduce mineral deposits in the  
pads andhelptoextendthelifeof Honeycombcoolingmedia.  
Do not run the unit in COOL mode with stale water in the tank.  
It is recommended to empty the tank and refill it with fresh  
water if the water has been standing in the tank for an  
extended periodof time  
The frequency for cleaning depends on local air and water  
conditions. For example, in areas where mineral content of  
the water is high, deposits may build up in the Honeycomb  
cooling media, restricting air flow. In this case, i t i s  
recommended to clean the Honeycomb cooling media every  
twomonths.  
For best results, allow the Honeycomb cooling media to dry  
after each use by turning off the cool function 15 minutes  
before turningtheunitoff.  
11  
 
TROUBLESHOOTING GUIDE  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
No dischargeof air  
Cordis notpluggedin  
Make sure cord is plugged in  
and try to turn the unit on by  
pressing buttons on control  
panel orremotecontrol.  
Power is noton  
Pump is notturned on  
Low /No water  
TurnonCOOLfunction  
Refill watertank  
Damaged pump  
Replace pump. Contact  
servicecentre  
When the product is used for  
the first time the Honeycomb  
cooling media will have an  
odour which will dissipate  
withinaweek of initial use.  
Odour omission  
Newunit  
Old unit  
There may be an algae issue.  
Replace the Honeycomb  
cooling media.  
servicecentre  
Contact  
12  
 
TROUBLESHOOTING GUIDE  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
Unit is making noise  
Calcium build up in blower  
Contact service centre.  
Pump will make noise if water  
level is near empty. Refill  
water tank.  
Low or no water in the water  
tank when COOL is selected  
Service Centre:  
Scott Brothers Limited  
1 Whiteside, Station Road,  
Holmes Chapel, Cheshire  
CW4 8AA, U.K.  
Tel +44 (0)1477 539 500  
Fax +44 (0)1477 539 530  
13  
 
TECHNICAL SPECIFICATIONS  
CL60PM  
MODEL NO.  
Voltage  
Frequency  
Wattage  
Water Tank Capacity  
Cooling Media  
Product Dimension  
Net Weight  
220-240 V  
50 Hz  
220 Watts  
60 Litre  
Honeycomb  
700 (L) x 466 (W) x 1017 (H)  
19 Kg  
Made in China  
ELECTRICAL WIRING DIAGRAM  
14  
 
Warranty  
Warranty on Honeywell Cooler  
We undertake by this Warranty to rectify free of charge any fault due to poor workmanship or  
faulty materials occurring in this Honeywell evaporative cooler within 1 year from the date of  
purchase. This undertaking is conditional upon the cooler being used only for personal  
domestic household or commercial purposes and installed and operated in accordance with  
our instructions and does not apply to consumable components such as cooling pads or  
adjustments as necessary due to the misuse of the cooler. Normal user maintenance is  
excluded.  
The benefits conferred by this warranty are in favour of the original retail purchaser and any  
person deriving title to the goods under or through such person and are intended to be  
separate from additional to all other rights and remedies which they may have in law in  
respect of the goods.  
The above warranty applies to the United Kingdom only.  
This warranty is in addition to your statutory rights and does not affect them in any way.  
15  
 
This page is intentionally left blank  
 
Autorised Distributor:  
Scott Brothers Limited  
1 Whiteside, Station Road  
Holmes Chapel  
Cheshire, CW4 8AA, U.K  
Tel +44 (0)1477 539 500  
Fax +44 (0)1477 539 530  
IM01-1009-000-000  
December 2009  
© 2009 AirTek International Corporation Limited  
The Honeywell Trademark is used under license from  
Honeywell International Inc.  
Honeywell International Inc. makes no representation or  
warranties with respect to this product.  
Manufactured by AirTek International Corporation Limited.  
 

Grizzly Nail Gun H8230 User Manual
Haier Freezer HFH 50 User Manual
HANNspree Flat Panel Television ST32 15H1 User Manual
Harbor Freight Tools Automobile Accessories 67649 User Manual
Harman Kardon Digital Camera AVR45 User Manual
Hawking Technology Digital Camera HNC300 User Manual
HP Hewlett Packard Welding System 3780A User Manual
Huey Chiao Bluetooth Headset HCB20 User Manual
Hunter Fan Fan 23802 User Manual
Imation Camcorder Hard Disk User Manual